In addition to the panel rib wall system rock wainscot was used on the exterior of the building.
Pre engineered metal building wall to roof detail.
Roof pitch the metal roofing panels shown in this manual require a min imum slope of 2 สบ per foot to ensure proper drainage.
After reviewing the framing and components that make up your building system explore how these 5 primary areas of focus result in 5 advantages your project will benefit from.
Wall cladding or sheeting roof cladding or sheeting rake or gable trim eave strut end wall girt sidewall girt purlin rigid frame end wall frame portal frame framed openings x bracing roof x bracing ridge cap valley multiple span columns mezzanine.
Double wall roof curb support guide.
Ceco is the brand chosen by builders throughout the u s.
Roof pitch the metal roofing panels shown in this manual require a mini mum slope of 2 per foot to ensure proper drainage.
Refer to the rain carrying table in this booklet for the maximum allowable panel length per slope that will provide adequate drainage.
Rigid is the leading manufacturer for metal buildings steel buildings pre engineered buildings hybrid buildings structural steel and metal building components including metal roof and wall panels accessories trim and componentized metal buildings.
Complete supplier of steel buildings.
For longer slopes and lower roof pitches contact fabral for other suitable profiles.
Roof slope the tangent of the angle that a roof surface makes with the horizontal usually expressed in units of vertical rise to 12 units of horizontal run.
Hover over the orange circles on the building below to see the names of each building element.
Section thru double wall curb.
Pbr downhill double wall curb base end lap at support beam.
Roof seamer a machine that crimps or folds adjacent edges of standing seam metal roof panels together to form a seam.
This project was a 16 000 sq.
Click on the thumbnails below to view enlarged drawings.
Pbr uphill double wall curb base end lap at support beam.
Refer to the rain carrying table in this booklet for the maximum allowable panel length per slope that will provide adequate drainage.
Single slope building creating a gable roof line.
For longer slopes and lower roof pitches contact fabral for other suitable profiles.
Single slope addition to an existing 16 000 sq.
Double wall roof curb base detail.
As a service to contractors architects and other looking for specific details and information regarding the inland building systems products.
Ceco building systems designs fabricates and supports metal buildings combining custom technology with attention to detail and a high value on the customer relationships we build.
For being the trusted expert in the design fabrication of pre engineered metal building systems.