A good way to test this out is to run the blower blower is apt to operate fine under 10 5 v if the blower runs then that means the battery supply may be under 10 5 v and thus its not able to open the furnace valve.
Rv furnace won t ignite.
The ducts carry the heated air from the furnace to the interior of the rv.
So you will have the fan running but thee wont be any heat or less heat.
After you activate the furnace the igniter would generate sparks and ignite the propane gas.
This is typically the problem if you can hear your furnace click on but it does not fire up.
So it goes without saying that if the igniter refuses to work your atwood hydro flame furnace won t light.
The blower starts the ignitor clicks but doesn t light.
We needed our furnace model suburban sf 30f a couple weeks ago and wouldn t you know it it wouldn t ignite.
A faulty or dirty ignition or sensor is a relatively easy fix so follow these steps and you may be able to solve the problem yourself.
What to do.
Rv furnace blower comes on but won t ignite.
Another common issue is when the blower begins to blow but the furnace still isn t igniting.
Rv furnace operates with a 10 5 v supply and at times if the battery is not able provide above 10 5v then the furnace wont ignite.
If it happens to be low power i merely replace the battery with a one that has the right voltage.
I made sure the gas lines were.
Normally this is an electrical issue.
The furnace may make a click sound but it wont start.
August 20th 2017.
A pilot light problem.
Forest river rv model.
The problem is when the blower works and the heater doesn t ignite it is the board inside heater it will have to be pulled out and replaced it is inside your heater unit chances are if you were at a camp site and you didn t have a device to control spikes it zapped your igniter board.
This usually solves the problem.
Page 1 of 2 furnace blower starts but won t ignite posted in outback hvac appliances.
Rv furnace clicks but won t start.
The internal furnace switch wont let the furnace ignite resulting in less heat.
The dsi is an acronym direct spart ignition it s an electronic igniter that uses a spark ignites the gas air mix.
Rv furnace blower comes on but won t ignite.
The pilot light or ignition sensor is usually the most common issue when your furnace will not ignite.
It tried three times before going into lockout and then needed to be reset at the ceiling unit.
This happens when the spark igniter try s to ignite the pilot light but fails.
The exhaust is an air outlet on the exterior of the rv that exhausts the gases produced during the combustion process the gases are a combination of carbon dioxide and carbon.